The MEDICOR Neonatal Warming and Resuscitation Table is a comprehensive solution designed to support safe, efficient neonatal care in delivery rooms and NICUs. Built on a heavy-duty mobile stand, it combines precise temperature regulation, advanced safety systems, and ergonomic design to support critical resuscitation and warming procedures.
Standard Manufacturer
Ships within 24 hours
The MEDICOR Neonatal Warming and Resuscitation Table is engineered to provide optimal thermal care and clinical efficiency for new born resuscitation and postnatal treatment. Built on a robust mobile stand with four anti-static swivel castors (two lockable, 150 mm), the unit ensures smooth manoeuvrability and secure positioning in demanding clinical environments. Protector bumpers on each side and a side handle/rail allow safe and easy positioning around the patient.
The infant lying surface features an anti-decubitus mattress that is fully X-ray compatible, supporting uninterrupted diagnostic procedures. A drawable X-ray cassette tray (35 × 65 cm) is integrated beneath the bed for convenient imaging. Four foldable side walls (17.5 cm height) provide patient safety, while manual continuous cradle tilting up to 10° in both directions enhances clinical positioning. Measurement lines, tube ports, and a rear name plate further improve usability and workflow efficiency.
A vertical column integrates the control system and display, including two monitor shelves and an IV pole. The 5-inch monochrome LCD screen displays key parameters such as set temperature, actual temperature, heating status, APGAR timing, and date/time. Graphic trend visualization for 3, 24, and 170 hours supports continuous monitoring and clinical review. The water-resistant, foil-covered soft-touch control panel includes safety lock, self-test, silence, and reset functions for reliable operation.
The overhead heater system features two ceramic heaters placed in a parabolic reflector and protected by a safety grid, delivering consistent and efficient radiant warmth. The heater head can be rotated by 30°, 90°, or 120° in both directions for optimal positioning. Integrated dimmable halogen and LED observation lights provide bright or soft illumination for procedures without disturbing the infant.
Advanced temperature regulation includes automatic warm-up, pre-warm mode (33°C), and manual heating control (0–100%). Both surface and skin temperature servo control modes are supported, with override ranges of 30–38°C and 34–38°C respectively. The unit supports both reusable and disposable skin temperature sensors.
Safety is central to the MEDICOR Neonatal Warming and Resuscitation Table. Visual and audible alarms monitor high/low temperature, multiple air temperature sensors, skin and mattress temperature, technical faults, mains failure, sensor errors, SpO₂, oxygen sensor failure, scale failure, and backup over-heat protection. A state-of-the-art microprocessor controller with an intelligent operating system performs continuous self-diagnostics, ensuring dependable performance at all times. The system is supplied with multilingual software versions, user manual, power cable, and fuse.