-Microprocessor based servo-controlled temperature system
-Control mode: Air mode
-Humidity is adjustable in two grades
-Set temperature, air temperature, heating power are displayed separately by LED
-Self - testing function, various failure alarms by audible and visual
->37°C temperature set function
-Triple protection for over temperature with separate cut off device, more
safety system
-The inclination of infant bed is adjustable -Single wall hood, 4 operating windows and 2 iris ports
-RS232 connector -Bracket with stand
-8.4" LCD display
-Temperature monitoring
-Temperature servo control
-Humidity Monitoring
-Humidity Servo Control
-Air temperature and body temperature control two modes
-Air mode and Baby mode controlled by micro-computer
-Use AC Power and DC Power alternatively, DC 12V or DC 24V Power on the ambulance
-Set temperature, air temperature, baby temperature and internal battery voltage can be displayed separately
-Double wall hood with side door so that the bassinet can be pulled out from it
-Natural air flow humidity
-The height of whole unit can be adjusted
-Oxygen cylinder and Oxygen supply system
-H14LED observe light, adjustable brightness
-Air temperature control range: 25°C~37°C 37.1°C~38°C
-Skin temperature control range: 32°C~37°C 37.1°C~38°C
-Air/Skin temperature sensor accuracy: ±0.3°C
-Warm-up time: ≤40min
-Ambulance type big trolley optional
-Microprocessor based servo
-controlled temperature system
-Two modes: Manual and automatic
-Set temperature and skin temperature display separately
-Anti-explosion micro crystal quartz for radiation source
-Self - testing function, various failure alarms by audible and visual
-Transparent protector can be folded down, with two infusion seals
-RS232 connector
-Microprocessor based servo
-controlled temperature system
-Three modes of control: Pre-warm, manual and automatic
-Set temperature and central skin temperature, peripheral temperature, air temperature, APGAR timer, heating power display separately
-8” LCD colorful touch screen
-Carbon steel heater for more effectivity
-Special design inclined heater head is more convenience for X ray test
-Digital skin temperature sensor, the data is accurate and stable
-Alarms functions for safety includes power failure, temperature deviation, temperature probe failure, over temperature
-Integral timer to record therapy time -78cm*64cm mattress
-Skin temperature trend for 5min
-Electric infant bed tilt angle is ± 12o -Transparent protector folded down, with two infusion seals
-Convenient X-ray cassette tray under infant bed -Electric height adjusted suit for operation
-With observe light, oxygen supply system and LED phototherapy